Product Attributes

Model No.DQB031-FB

BrandDYX

Power Source:Electric

Usage:DC PUMP

Pressure:Low Pressure

Current:<500mA

Structure:Diaphragm Pump

Voltage:3.0V

Flow Rate:0.6-1.6L/Min

Noise:<60db

Material:Plastic and metal alloy

Application:smart toilet

Packaging & Delivery
Selling Units : Piece/Pieces
Package Type : Export Carton
Picture Example :
DYX mini air pump automatic locking long screws
Flow rate test
Product Description

Working Principle and Characteristics Of Small Diaphragm Vacuum Pump

Micro elctric vacuum pump is a pump that uses a micro DC motor (usually 5V, 12V, 24V electric motor) as the power driving device.

It drives the internal mechanical eccentric device to perform eccentric motion, which drives the internal diaphragm to perform reciprocating motion.

This reciprocating motion affects the fixed volume pump chamber the air is compressed (when compressed, the exhaust port is closed, and the exhaust port is opened to form a slight positive pressure) and stretched (when compressed, the exhaust port is closed, and the exhaust port is opened to form a negative pressure).

There is a pressure difference between the pump suction port and the external atmospheric pressure. Under the effect of the pressure difference, the gas is pressurized (sucked) into the pump chamber and then discharged from the exhaust port.

mini vacuum pump working principle

Why can micro vacuum pumps be used for negative pressure physiotherapy, gas detection and adult products?

Micro vacuum pumps can be used for negative pressure physiotherapy, gas detection and adult products, mainly because they have the following characteristics:

1. Generate negative pressure: The Mini Vacuum Pump can generate negative pressure through air extraction, thereby promoting blood circulation, reducing inflammation, relieving pain, etc.

2. Gas collection and analysis: Micro vacuum pumps can be used for gas collection and analysis, such as respiratory gas analysis, blood gas analysis and other fields.

3. Auxiliary treatment: In the treatment of some diseases, micro vacuum pumps can be used as auxiliary treatment tools, such as for wound care, dental surgery, etc.

4. Adult products: Micro vacuum pumps are also used in adult products, such as sex toys, etc.

mini vacuum pump for adult products


How to realize the automatic shut-off function of the DC Small Vacuum Pump?

The automatic shutdown function of the DC Electric Vacuum Pump is usually implemented through a control circuit. Specifically, the automatic shut-off function of the Small Vacuum Electric Pump is achieved by detecting the vacuum degree through a sensor. When the vacuum degree reaches the set value, the sensor will send a signal and the control circuit will automatically shut down the vacuum pump. This automatic shut-off function can avoid air bag rupture caused by over-vacuuming or air bag explosion caused by over-inflation, thus protecting the safety of users.

It should be noted that different micro vacuum pumps may have different control circuits and sensors, so the automatic shutdown function may be implemented slightly differently. If you need to use a micro vacuum pump and understand how its automatic shut-off function is implemented, it is recommended to read the product instructions carefully or consult the manufacturer for more accurate information.


Technical Specification

Voltage DC3.0V Current 500mA
Flow 0.8-1.6LPM Pressure 320-500mmHg
Lifespan 30000 cycles Noise 60dB


Does the Small Electric Vacuum Pump have the function of preventing back suction?

Most micro vacuum pumps have a back suction prevention feature. Preventing back suction means preventing external gas from entering the inside of the pump, thereby maintaining pump performance and preventing contamination. The anti-back suction function of a micro vacuum pump is usually achieved through one-way valves at the air inlet and exhaust port. These one-way valves ensure that only gas can enter the pump from the outside and be discharged through the exhaust port without reverse flow. This backdraft protection protects the parts and diaphragms inside the pump and maintains pump performance and reliability.


Dimension Drawing

                                         dqb031-fb dimension


How does the anti-back suction function of the Mini Electric Vacuum Pump improve product comfort and service life?

The anti-back suction function of the micro vacuum pump can improve product comfort and service life, mainly through the following aspects:

1. Reduce discomfort: The anti-reverse suction function can prevent users from feeling discomfort during the pumping process, such as preventing blood, milk and other body fluids from being sucked into the pump, reducing harm to the body and discomfort.

2. Improve product performance: The anti-back suction function can improve the performance and accuracy of the product. For example, in the fields of medical equipment, laboratories, etc., the anti-back suction function can ensure that the equipment is more accurate and reliable, and improve the use effect and service life.

3. Reduce the failure rate: The anti-back suction function can reduce the failure rate of the product, for example: preventing blood, milk and other body fluids from entering the pump, avoiding corrosion and damage to the internal parts of the pump, thereby extending the service life of the product.

4. Ergonomic design: The design of the anti-back suction function is in line with ergonomic principles, which can better adapt to the needs of users and improve the comfort and use experience of the product.


Flow Chart

                                                                              dqb031-fb chart


Mini Pumps selection and use
1. Choose the appropriate pump type and model based on actual needs.
2. During use, parameters such as flow and pressure should be adjusted reasonably to avoid overload operation.
3. Pay attention to the operating environment of the pump and avoid using it in harsh environments such as humidity, high temperature, and dust.
4. After use, the power should be turned off to avoid prolonged power on.
Maintenance and upkeep of pumps
1. Regularly check the operation status of the pump, including whether there are abnormal noises, oil leaks, and other phenomena.
2. Regularly clean the air intake and exhaust ports to keep them unobstructed.
3. Regularly replace the lubricating oil to ensure the lubrication effect of the equipment.
4. When not in use for a long time, the pump should be cleaned and properly stored.
Home> Products> Mini Diaphragm Pump> Small Membrane Pump> Mini DC Membrane Vacuum Air Pump
Send Inquiry
*
*

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send